Modification
in different versions
v2.08
Caution: After the update, the system
performs a system reset. This will delete all
calibration- and programming data. You have to calibrate and reprogramm the
system
after the update. Please check, if you need the new functions in v2.08
![](../images/bullet_plus.gif) Variable
socket: If you change from a variable to a static socket, you´ve
seen furthermore the
value of the variable socket in the display.
![](../images/bullet_plus.gif) Timer:
You can now set 32 different procedures whith different
values to one variable socket.
![](../images/bullet_plus.gif) Intervall:
Like timer: 32 different procedure on one socket.
![](../images/bullet_plus.gif) External
display: Blank between day and date insertet
![](../images/bullet_plus.gif) Control:
After disabling a controlfunction, the system does not
respond.
v2.09
![](../images/bullet_plus.gif) Programming
Level: There was no difference between "normal" and profi" mode.
No mater what you
select, the system was always in the profi mode.
v2.10
![](../images/bullet_plus.gif) Lunar
Phase : Problems in simulation mode "on" - Timezone wasn´t
recognized
![](../images/bullet_plus.gif) Conductivity
: New conductivity display options "salinity" and "density"
v2.11
![](../images/bullet_plus.gif) Conductivity
: There was an error on calibrating on temperature other than 25°C.
v2.11a
(English version only)
![](../images/bullet_plus.gif) Translation:
New menu text
v2.11a
(French version only)
![](../images/bullet_plus.gif) Translation:
There was an error by few words in the display text
v2.12
![](../images/bullet_plus.gif) Day/Night-Simulation:
Using a socket with power regulation causes the socket go off for a small
time
period at the beginning of the sunset
v2.13
![](../images/bullet_plus.gif) O2:
O2-Measurement needs at minimum this version
v2.14
![](../images/bullet_plus.gif) O2:
If calibrating of oxygen modul was not successful and "Buffer: 100" don't
appears on the display, it has had to carry
out a so-called Reset . This has erased all former programming.
DO NOT DOWNDATE from v2.15 to v2.14 ! !
!
v2.15
![](../images/bullet_plus.gif) Softwareversion
for new aquastar hardware. No additional software functions.
v2.16
Caution: After the update, the system
performs a system reset. This will delete all
calibration- and programming data. You have to calibrate and reprogramm the
system
after the update. Please check, if you need the new functions in v2.16.
![](../images/bullet_plus.gif) manual
and automatic feeding break. (supplementary sheet (feeding
break))
![](../images/bullet_plus.gif) Day/Night--Simulation
for static sockets are now able to be switched off .
![](../images/bullet_plus.gif) When
operating in conjunction with a daytime/night-time simulation,
a switchable socket switches on 30 minutes
after sunrise and then switches off when the sun begins
to set ( 30 minutes before the time set for "Off").
iks aquastar version 2.16 english (
75 kB )
v2.17
Caution: After the update, the system
performs a system reset. This will delete all
calibration- and programming data. You have to calibrate and reprogramm the
system
after the update. Please check, if you need the new functions in v2.17.
![](../images/bullet_plus.gif) Manual,
half-automatic and automatic feeding break.
![](../images/bullet_plus.gif) As
soon as 2000 measurement chains were stored, the oldest measurement
chains are written over.
![](../images/bullet_plus.gif) Feeding
break caused an error at the current (high/low tide) simulation
at variable-output sockets.
![](../images/bullet_plus.gif) If
data (chains of measurement) is transferred to a PC, the
memory (data) is not automatically cleared. Erasing
memory is done with the aquastar menu item "Measurement
settings - memory" or with the software
winsoft v0.17.2 .
![](../images/bullet_plus.gif) aquastar
software v2.17 is compatible to winsoft v0.17.2 concerning
the menu item "Read programming data" and "Write
programming data" .
iks aquastar version 2.17 english (
75 kB )
v2.18
![](../images/bullet_plus.gif) In
extremely rare cases a sensor error arose with version 2.17 even with new
oxygen sensors during the calibration.
v2.19
Caution: After the update, the system
performs a system reset. This will delete all calibration- and programming
data. You have to calibrate and reprogramm the system after the update. Please
check, if you need the new functions in v2.19. Only compatible with winsoft
V0.19.0
![](../images/bullet_plus.gif) pH
control with delay time (e.g. for garden ponds)
![](../images/bullet_plus.gif) Menu
item "SetMeasurement - Display - Temperature: °C or °Fahrenheit.
If Display "°Fahrenheit" is chosen,
then the stored data and the regulation values have the same unit
of measurement => °F.
iks aquastar version 2.19 english (
76 kB )
v2.20
![](../images/bullet_plus.gif) SMS-Controller: This version is only necessary, if broadcasting a short message (SMS) with the cause "no control".
iks aquastar version 2.20 english ( 85 kB )
v2.21
![](../images/bullet_plus.gif) If using the newest conductivity module (grey and blue housing (picture) , since june 2004) this version must be loaded.
iks aquastar version 2.21 english ( 85 kB )