FAQs
(Frequently Asked Questions) for winsoft since version v0.19
1.) aquastar programming interface:
If I change a number entry in a number field
(e.g. "on" or "off" times at the time functions , control
values for "value day" or "value night") and afterwards
I load the new programming data on the iks aquastar, why was the new number
entry in the aquastar not taken over?
After you changed a number in a field, the flashing cursor
may not remain in this field. After you changed a number in a field,
move the cursor with the mouse into another field whose numerical value
you do not want to change any longer. If there is only one number field
in a special window (e.g. measured value attitudes - > storage - > memory
interval), then you have to click simply on an active "radio button" again
(e.g. clear memories ? : if "no button" is active, then press
this button again).
2.) Connecting problems - problems while starting
winsoft 0.19.0
The PC program winsoft is not able to establish contact to the aquastar, even
though it has worked before.
In what kind of mode situates your aquastar ? In operation mode (running) or
in programming mode ? We have found out, that the aquastar reacts in a better
way to the asynchronous commands of the software winsoft, if it situates
in operation mode.
After
winsoft was started the firmware version of the aquastar was not correctly
detected . ( Message : "aquastar software version : 2. " ) and
the message " Possibly you use an older version of the aquastar software
than 2.19 ! " appears.
Solution: In the system settings below the properties of the corresponding
COM serial port change the "Receive Buffer"-setting for the FIFO
to "low".
Approach
to Windows 2000:
Start - Settings - Systemsteuerung - System - Hardware - Geräte-Manager
- Ports (COM und LPT) - Serial Port (COMx) (Doppel-Click) - Port Settings -
Advanced - Advanced Settings for COMx - Receive Buffer - push the slider to "Low
(1)"
Approach
to Windows 98:
Start, Go to Settings, Control Panel, Click on System, System Properties, Device
Manager, Ports (COM & LPT) Communication Port (COM x), Port Settings,(Bits
per Seconds: 9600 - Data bits: 8 - Parity: None - Stop bits: 1 - Flow Control:
None) Advanced, Advanced Port Settings, Receive Buffer: Low (1) Transmit Buffer:
Low (1), Click OK Buttons, close all windows and restart windows 98.
Starting
winsoft , after the request of the firmware version of aquastar the
following message appears : "Aquastar doesn't respond ! Please
check cable connection ! "
Try to achieve a connection to aquastar with the Windows "Hyperterminal" program.Settings:
Bits per second : 9600 ; Data bits: 8 ; Parity: No ; Stop bits: 1 ; Handshake
: No.
3.) Message "The configured serial port
is not valid" when program starts.
When starting winsoft, don't be worry about the message "The
configured serial port is not valid. Please choose another port". In
this special case, this message is unimportant, you can choose all free ports
of your PC
FAQs
serial interface
1.) absence of serial interface::
Both serial interfaces of my PC are occupied
by a analog modem and a "mouse" respectively my portable PC (laptop)
doesn't make a serial interface available. Can I connect the iks aquastar
to the PC anyway ?
If your PC has a USB-interface, you can make an additional
serial interface available to the PC with an USB adapter for serial interface
(data cable) over the USB-port. Besides the COM1 und COM2 interface you can
also choose the COM3 interface. The USB adapter is available in the internet-shop http://www.datenkabel-discounter.de .
The device driver for Windows 95 98 ME 2000 and XP will be sent per E-Mail
from the internet-shop. Please notice, that the Windows XP device driver
is not qualified for the logo "Designed for Windows XP". You have
also the ability to download the device driver here: Download
A Bedieningshandleiding for installation for the several operating systems can be downloaded
here: www.bafo.com.tw -> product BF-810
|